RXM Model 4210-3
RXM Chassis Location Primary
Cable Type Single-mode
Cable Length Limit 7.5 miles (12 kilometers)
Connectors 6/remote site


Remote Extender Module
(RXM)
RXMs and chassis allow I/O modules to be located several kilometers from
the main chassis. RXM sets, consisting of three identical modules, serve as
repeaters and extenders of the Tricon I/O bus and provide ground loop isolation. A primary RXM set supports three
remote locations by connecting to three remote RXM sets housed in a remote chassis. See “System Configuration” on
page 11 regarding configurations that use RXMs.

 

SET:TYPE MODULE, APPLICATION PCIMS SYSTEM, STANDARD CSA,FFT: RXM CHASSIS LOCATION:
PRIMARY;CABLE TYPE: SINGLE-MODE; CABLE LENGTH LIMIT: 12KM;CONNECTORS: 6;MODEM PORTS: FIBRE OPTIC WITH ST
CONNECTORS;SET CONSIST OF 3 MODULES,Mnfr: TRICONEX Mnfr Part No: 4210-3,Suppl: YOKOGAWA ENGINEERING ASIA PTE LTD SupplP/N: UNKNOWN, CATALOGUE: 9791007-011 Rev: 0

 

For more detailed specifications, you can visit the links provided:

 Tricon Triconex 4210 Remote ExtenderModule

 

Other hotselling

PROCESSOR,MAIN,W/16 MB SRAM(V10.0) PART NO: 3008 - V10.0 MANUFACTURER: TRICONEX TRICONEX 3008 - V10.0
PRIMARY RXM FOR SINGLE MODE FIBER OPTIC TRICONEX 4210
ANALOGUE INPUT,WA136937-003-001-001 TRICONEX 3704E
ANALOGUE INPUT,WA136937-003-001-001 TRICONEX 3704E
MODULE,AI,TRM,64PTS,0-5VDC,SINGLE-ENDEDTMR ANALOG INPUT MODULE, 64 POINTS, 0-5 VOLT DC, SINGLE-ENDED // МОДУЛЬ, AI, TRM, 64PTS, 0-5В ПОСТ. ТОКА, ОДНОКОНЕЧ. ТЕМП. МОДУЛЬ АНАЛОГОВОГО ВВОДА, 64 ТОЧКИ, 0-5 В ПОСТОЯННОГО ТОКА, ОДИНАРНЫЙ SCHNEIDER ELECTRIC 3720
MODULE,OUTPUT,DIGITAL,SUPERVISED,16POINTMODULE, OUTPUT, DIGITAL, SUPERVISED, 16 POINT. 24VDC, 10WATT. MFG TRICONEXCORP, P.N 3624, TYPE TMR. // МОДУЛЬ, ВЫВОД, ЦИФР., КОНТРОЛИРУЕМЫЙ, 16-ТОЧ. МОДУЛЬ, ВЫХОДНОЙ, ЦИФРОВОЙ, КОНТРОЛИРУЕМЫЙ, 16 ТОЧЕК. 24 В ПОСТОЯННОГО ТОКА, 10 ВАТТ. ПРОИЗВОДИТЕЛЬ TRICONEXCORP, КОД ДЕТАЛИ 3624, ТИП TMR. TRICONEX 3624
ANALOGUE INPUT,WA136937-003-001-001 // АНАЛОГОВЫЙ ВХОД, WA136937-003-001-001 TRICONEX 3704E
MODULE,COMMUNICATION,RJ45,4351B,V11.5ITEM_DESCRIPTION: COMMUNICATION MODULE SPECIAL_FEATURES: ASSMBLY MOD TCM COMM(RJ45) FOR SYSTEM V11.5 // МОДУЛЬ СВЯЗИ,RJ45,4351B,V11.5 ОПИСАНИЕ ИЗДЕЛИЯ: МОДУЛЬ СВЯЗИ ОСОБЫЕ ПАРАМЕТРЫ: КОМПОНОВКА MOD TCM COMM (RJ45) ДЛЯ СИСТЕМЫ V11.5 TRICONEX 4351B,V11.5
PROCESSOR,MAIN,ASSY,3009,V11.5,TRICONEXNOUN_IDENTIFIER: MOD MAIN PROCESSOR ASSEMBLY SPECIAL_FEATURES: FOR SYSTEM V11.5 // ГЛАВНЫЙ ПРОЦЕССОР В СБОРЕ,3009,V11.5,TRICONEX ИДЕНТИФИКАТОР: ГЛАВНЫЙ ПРОЦЕССОР В СБОРЕ ОСОБЫЕ ПАРАМЕТРЫ: ДЛЯ СИСТЕМЫ V11.5 TRICONEX 3009,V11.5
MAIN CHASSIS,ASSEMBLY,8120E,TRICONEXITEM_DESCRIPTION: MAIN CHASSIS ASSEMBLY SPECIAL_FEATURES: HIDEN ENH PERF // ОСНОВНЫЕ ШАССИ, В СБОРЕ,8120E,TRICONEX ОПИСАНИЕ ИЗДЕЛИЯ: ОСНОВНОЕ ШАССИ В СБОРЕ, ОСОБЫЕ ПАРАМЕТРЫ: HIDEN ENH PERF TRICONEX 8120E
BAFFLE,CHASSIS,2000361-001,TRICONEXITEM_DESCRIPTION: CHASSIS BAFFLE // ПЕРЕГОРОДКА,ШАССИ,2000361-001,TRICONEX ОПИСАНИЕ ИЗДЕЛИЯ: ПЕРЕГОРОДКА КОРПУСА TRICONEX 2000361-001
CABLE,40FT,4000206-540,TRICONEXNOUN_IDENTIFIER: CABLE LENGTH: 40 FT VOLTAGE_RATING: 24 VDC SPECIAL_FEATURES:AI,LOW SMOKE ZERO HALOGEN LSZH JACKET // КАБЕЛЬ,40ФУТ,4000206-540,TRICONEX ИДЕНТИФИКАТОР: ДЛИНА КАБЕЛЯ: 40 ФУТОВ НОМ. НАПРЯЖЕНИЕ: 24 В ПОСТ. ТОКА ОСОБЫЕ ПАРАМЕТРЫ: КОНУТР ДЫМОВОГО ГАЗА С НУЛЕВЫМ СОДЕРЖАНИЕМ ГАЛОГЕНА LSZH TRICONEX 4000206-540
SWITCH,DISCONNECT,100A,3POLEDISCONNECT SWITCH, FUSED, 100A, 3 POLE, CLASS J, USE 10X10 SHAFT PART NO:GS2JU3 MANUFACTURER: SCHNEIDER ELECTRIC // ПЕРЕКЛЮЧАТЕЛЬ-РАЗЪЕДИНИТЕЛЬ,100A,3ПОЛЮСА ПЕРЕКЛЮЧАТЕЛЬ-РАЗЪЕДИНИТЕЛЬ, ПЛАВК.ПРЕДОХР., 100A, 3 ПОЛЮСА, КЛАСС J, ИСПОЛЬЗОВАТЬ 10X10 ВАЛ АРТИКУЛ:GS2JU3 ПРОИЗВОДИТЕЛЬ: SCHNEIDER ELECTRIC SCHNEIDER ELECTRIC GS2JU3
MODULE, 4351B, V11.2 COMM, RJ45 COPPERMODULE, TRICONEX COMMUNICATION, 4351B WITH COPPER (RJ45), BUILD 275 FOR SYSTEMV11.2 // МОДУЛЬ, 4351B, V11.2 КОММ., RJ45 МЕДН. МОДУЛЬ, СВЯЗЬ TRICONEX , 4351B МЕД. (RJ45), В СБОРЕ 275 ДЛЯ СИСТЕМЫ В.11.2 TRICONEX 4351B BUILD 275
REMOTE RXM,FIBER OPTIC,SGL MODE,4211RREMOTE RXM FOR SINGLE MODE FIBER OPTIC PART NO: 4211 MANUFACTURER: TRICONEX // УДАЛ. RXM, ВОЛОКОННО-ОПТИЧЕСКИЙ, ОДНОМОД., 4211R УДАЛ. RXM ДЛЯ ОДНОМОДОВОЙ ВОЛОКОННО-ОПТИЧ., АРТИКУЛ: 4211 ПРОИЗВОДИТЕЛЬ: TRICONEX TRICONEX 4211
SWITCH,DISCONNECT,100A,3POLEDISCONNECT SWITCH, FUSED, 100A, 3 POLE, CLASS J, USE 10X10 SHAFT PART NO:GS2JU3 MANUFACTURER: SCHNEIDER ELECTRIC // ПЕРЕКЛЮЧАТЕЛЬ-РАЗЪЕДИНИТЕЛЬ,100A,3ПОЛЮСА ПЕРЕКЛЮЧАТЕЛЬ-РАЗЪЕДИНИТЕЛЬ, ПЛАВК.ПРЕДОХР., 100A, 3 ПОЛЮСА, КЛАСС J, ИСПОЛЬЗОВАТЬ 10X10 ВАЛ АРТИКУЛ:GS2JU3 ПРОИЗВОДИТЕЛЬ: SCHNEIDER ELECTRIC SCHNEIDER ELECTRIC GS2JU3
LITHIUM BATTERY, C-SIZE, 3.6VDC FOR MAIN CHASIS MANUFACTURER: TRICONEX // ЛИТИЙ. БАТАРЕЯ, C-РАЗМЕР, 3.6В ПОСТ. ТОКА ДЛЯ ОСНОВНОГО ШАССИ, ПРОИЗВОДИТЕЛЬ: TRICONEX TRICONEX 0
TMR ANALOG INPUT MODULE, 64 POINTS, 0-5 VOLT DC, SINGLE-ENDED SCHNEIDER ELECTRIC 3720
ANALOGUE INPUT,WA136937-003-001-001 TRICONEX 3704E
PRIMARY RXM FOR SINGLE MODE FIBER OPTIC TRICONEX 4210
DIGITAL INPUT,WA136937-003-001-001 * REFER ATTACHMENT FOR SPECIFICATION TRICONEX 3504E
Show All
Blog posts
Show All
Optimizing Fault Handling in Industrial Automation with Real-Time Data
plcdcspro

Optimizing Fault Handling in Industrial Automation with Real-Time Data

In the modern landscape of factory automation, even the most advanced control loops encounter unexpected disruptions. Effective fault handling requires more than just stopping a machine; it demands a deep understanding of cause, severity, and actionable communication. By leveraging real-time data, manufacturers can transform chaotic alarm environments into streamlined, safe, and highly efficient operations.

Essential PLC Selection Guide: 5 Critical Features for Industrial Automation Success

Essential PLC Selection Guide: 5 Critical Features for Industrial Automation Success

Navigating the complex landscape of industrial control systems requires more than just a glance at a datasheet. For those new to industrial automation, the sheer volume of technical specifications can be overwhelming. While many features are specialized, a core set of functionalities dictates whether a PLC (Programmable Logic Controller) will meet your project goals.

Selecting the right hardware impacts long-term maintenance and scalability. Below are five essential features every engineer must evaluate before committing to a specific control platform.

Navigating the 2026 Shift: NIS2 and CRA in EU Industrial Automation

Navigating the 2026 Shift: NIS2 and CRA in EU Industrial Automation

The European industrial landscape faces a transformative regulatory era starting in 2026. Process industries, particularly chemical and energy sectors, must now navigate two powerful legislative frameworks: the NIS2 Directive and the Cyber Resilience Act (CRA). Together, these laws convert cybersecurity from a voluntary "best practice" into a mandatory requirement for market access and operational continuity.