Configured for control execution and I/O communication in Yokogawa CENTUM VP and CENTUM CS 3000 Distributed Control Systems, the Yokogawa CP401-10 (CP401 Processor Module) provides central processing within a Field Control Unit (FCU). It executes control logic, sequence control, loop calculations, and I/O communication management through V net and ESB bus interfaces.
| Parameter | Specification |
|---|---|
| Model | CP401-10 |
| Brand | Yokogawa |
| Origin | Not specified in supplied data |
| Product Type | Processor Module |
| Processor Architecture | MIPS R5000 32-bit RISC |
| Main Memory Capacity | 32 MB |
| Communication Bus | V net / ESB bus interfaces |
| Power Supply | 5 VDC |
| Current Consumption | Approx. 2.6 A |
| Power Consumption | Approx. 13 W at 5 VDC and 2.6 A |
| Operating Temp | 0 deg C to 55 deg C |
| Operating Humidity | 10% to 90% RH, non-condensing |
| Mounting Type | Rack mountable in FCU rack/backplane |
| Dimensions | 130 mm x 100 mm x 42 mm |
| Weight | 0.35 kg |
| Application Platform | CENTUM VP / CENTUM CS 3000 |
The CP401-10 performs processor-level control and I/O communication functions through the V net and ESB bus interfaces. The supplied specifications do not identify a direct 4-20 mA HART field interface on the CP401-10 itself. HART signal acquisition or transmission therefore depends on the associated field I/O hardware installed in the FCU configuration.
The processor module is responsible for executing control calculations and managing communication with the configured I/O subsystem. Physical field signal conditioning, loop termination, and HART channel interfaces should be assigned to the applicable I/O modules rather than to the CP401-10 unless explicitly specified by the system configuration.
Q: Does the CP401-10 provide direct 4-20 mA HART channel connections?
A: The supplied data does not specify direct 4-20 mA HART channel connections for the CP401-10. The module is specified as a processor with V net and ESB bus interfaces.
Q: What is the specified power requirement of the CP401-10?
A: The module requires 5 VDC and has an approximate current consumption of 2.6 A. Based on these supplied values, the electrical load is approximately 13 W.
Q: Is hot-swap operation specified for the CP401-10?
A: No hot-swap capability is specified in the supplied technical data. Replacement or removal should therefore follow the applicable Yokogawa FCU maintenance procedure.
At PLC DCS Pro Ltd., we are committed to ensuring the quality of our products. Our one-year warranty provides coverage for any defects in material or workmanship, excluding damages caused by deliberate misuse.
This warranty encompasses all instances of product malfunction or failure due to inherent manufacturing flaws, with the exception of intentional damage.
To avail of warranty services, please notify us of any quality-related issues within the warranty period. We may conduct online troubleshooting and examination as needed.
We understand the importance of prompt service. Therefore, we cover return shipping costs for warranty-related returns within the first month of supply. Within three months of supply, we cover one-way shipping costs for warranty-related returns. After three months, the customer is responsible for shipping costs both ways.

Efficient delivery tailored to urgent requirements.
A broad array of stock guarantees prompt availability.
Assuring authenticity and excellence in PLC & DCS parts.
Providing reliable support to clients worldwide.