ข่าวสาร

Impulse Line Slope Design for Accurate Pressure Measurement

Impulse Line Slope Design for Accurate Pressure Measurement

Impulse line slope is critical for accurate pressure measurement in process plants. This article explains why sloping installation prevents condensation accumulation in gas service, gas pockets in liquid service, and solidified material blockages. Learn the engineering principles behind slope direction selection, minimum angle requirements, and systematic installation procedures for reliable pressure signal transmission.
Diaphragm Seal Mounting Techniques for Harsh Process Applications

Diaphragm Seal Mounting Techniques for Harsh Process Applica...

Diaphragm seals protect pressure instruments from corrosive, high-temperature, and abrasive process fluids. This article covers complete mounting techniques including direct, remote, extended, flange, and threaded configurations. Learn fill fluid selection criteria, capillary tube sizing, temperature effects on measurement accuracy, and systematic installation procedures for reliable pressure measurement in harsh industrial environments.
Temperature Multiplexer Fault Analysis: Modbus Address Conflict and PLC Communication Failure

Temperature Multiplexer Fault Analysis: Modbus Address Confl...

A real plant shutdown incident reveals critical lessons about temperature multiplexer configuration and Modbus communication. This article analyzes how 18 temperature sensors suddenly failed, causing operational confusion and a 30-minute data blackout. Learn the root cause of address conflicts, proper spare device management, and systematic troubleshooting procedures for temperature monitoring systems in process plants.
Flow Meter Troubleshooting: Endress+Hauser Promag 53 and Electromagnetic Measurement Diagnostics

Flow Meter Troubleshooting: Endress+Hauser Promag 53 and Ele...

Electromagnetic flow meters provide accurate measurement for conductive liquids but require proper installation and periodic verification. This article covers comprehensive troubleshooting of the Endress+Hauser Promag 53 electromagnetic flow meter, including sensor grounding verification, electrode coating detection, empty pipe diagnostics, and signal quality assessment. Practical sections address grounding practices, cable shielding, process conductivity requirements, and systematic fault isolation procedures.
Temperature Transmitter Calibration: Rosemount 644 and Foundation Fieldbus Configuration

Temperature Transmitter Calibration: Rosemount 644 and Found...

Accurate temperature measurement requires proper transmitter calibration and sensor matching. This article covers complete calibration of the Rosemount 644 temperature transmitter, including RTD sensor characterization, transmitter trim procedures, Foundation Fieldbus configuration, and integration with DCS systems. Practical sections address cold junction compensation, sensor diagnostics, common error sources, and establishing calibration intervals per IEC 60584 standards.
Industrial Ethernet Switch Configuration: Moxa EDS-510E and PROFINET IRT Network Design

Industrial Ethernet Switch Configuration: Moxa EDS-510E and ...

Industrial Ethernet switches form the backbone of modern automation networks. This article covers complete configuration of the Moxa EDS-510E managed switch, including Turbo Ring redundancy setup, PROFINET IRT optimization, VLAN segmentation, and QoS prioritization. Practical sections address cable selection, grounding practices, multicast filtering, and troubleshooting common network faults in harsh industrial environments.