{"product_id":"yokogawa-cp401-10-processor-module","title":"Yokogawa CP401-10 Processor Module","description":"\u003ch2\u003eYokogawa CP401-10 Processor Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for control execution and I\/O communication in Yokogawa CENTUM VP and CENTUM CS 3000 Distributed Control Systems, the \u003cstrong\u003eYokogawa CP401-10\u003c\/strong\u003e (\u003cstrong\u003eCP401\u003c\/strong\u003e Processor Module) provides central processing within a Field Control Unit (FCU). It executes control logic, sequence control, loop calculations, and I\/O communication management through V net and ESB bus interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP401-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProcessor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Architecture\u003c\/td\u003e\n\u003ctd\u003eMIPS R5000 32-bit RISC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Memory Capacity\u003c\/td\u003e\n\u003ctd\u003e32 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Bus\u003c\/td\u003e\n\u003ctd\u003eV net \/ ESB bus interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 2.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 13 W at 5 VDC and 2.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eRack mountable in FCU rack\/backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 mm x 100 mm x 42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Platform\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP \/ CENTUM CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Communication and HART Interface Scope\u003c\/h3\u003e\n\u003cp\u003eThe CP401-10 performs processor-level control and I\/O communication functions through the V net and ESB bus interfaces. The supplied specifications do not identify a direct 4-20 mA HART field interface on the CP401-10 itself. HART signal acquisition or transmission therefore depends on the associated field I\/O hardware installed in the FCU configuration.\u003c\/p\u003e\n\u003cp\u003eThe processor module is responsible for executing control calculations and managing communication with the configured I\/O subsystem. Physical field signal conditioning, loop termination, and HART channel interfaces should be assigned to the applicable I\/O modules rather than to the CP401-10 unless explicitly specified by the system configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CP401-10 provide direct 4-20 mA HART channel connections?\u003c\/p\u003e\n\u003cp\u003eA: The supplied data does not specify direct 4-20 mA HART channel connections for the CP401-10. The module is specified as a processor with V net and ESB bus interfaces.\u003c\/p\u003e\n\u003cp\u003eQ: What is the specified power requirement of the CP401-10?\u003c\/p\u003e\n\u003cp\u003eA: The module requires 5 VDC and has an approximate current consumption of 2.6 A. Based on these supplied values, the electrical load is approximately 13 W.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swap operation specified for the CP401-10?\u003c\/p\u003e\n\u003cp\u003eA: No hot-swap capability is specified in the supplied technical data. Replacement or removal should therefore follow the applicable Yokogawa FCU maintenance procedure.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the CP401-10 in the designated FCU rack or backplane position.\u003c\/li\u003e\n\u003cli\u003eVerify that the FCU backplane and associated bus interfaces are compatible with the CP401-10 before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm the 5 VDC supply and available current capacity before energizing the module.\u003c\/li\u003e\n\u003cli\u003eMaintain correct module orientation and mechanical engagement with the rack\/backplane connector.\u003c\/li\u003e\n\u003cli\u003eRoute power and communication wiring separately from high-current switching conductors where practical.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shield termination practices for associated communication and I\/O wiring according to the Yokogawa system installation documentation.\u003c\/li\u003e\n\u003cli\u003eDo not assign direct field loop wiring to the processor module unless the hardware documentation explicitly identifies the corresponding interface.\u003c\/li\u003e\n\u003cli\u003eObserve the specified 0 deg C to 55 deg C operating temperature range and 10% to 90% RH non-condensing humidity range.\u003c\/li\u003e\n\u003cli\u003eBefore replacement, verify system power and maintenance-state requirements because hot-swap capability is not established by the supplied data.\u003c\/li\u003e\n\u003cli\u003eAfter installation, verify module recognition, bus communication, and I\/O communication status through the applicable CENTUM engineering and maintenance functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43671602954307,"sku":"CP401-10","price":234.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/CP401-11.png?v=1741331546","url":"https:\/\/www.plcdcspro.com\/th\/products\/yokogawa-cp401-10-processor-module","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}