{"product_id":"yokogawa-adv151-e00-s2-digital-input-module","title":"Yokogawa ADV151-E00 S2 Digital Input Module","description":"\u003ch2\u003eYokogawa ADV151-E00 S2 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV151-E00 S2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADV151\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for 24 V DC discrete signal acquisition within Yokogawa CENTUM VP and CENTUM CS 3000 Field Enclosure I\/O (FIO) systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-E00 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e32-Channel Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e24 V DC sink\/source digital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e32 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CENTUM CS 3000 DCS with FIO architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e18.0 to 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Allowable Voltage\u003c\/td\u003e\n\u003ctd\u003e30.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA +\/- 20% per channel at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 8 ms for status input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum ON Detection Time\u003c\/td\u003e\n\u003ctd\u003e20 ms for pushbutton input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum ON\/OFF Cycle\u003c\/td\u003e\n\u003ctd\u003e25 Hz for pushbutton input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Current Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 500 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Layout\u003c\/td\u003e\n\u003ctd\u003e16 channels per common group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupports dual-redundant configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.0 in x 1.0 in x 5.0 in (12.7 cm x 2.5 cm x 12.7 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 500 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop and DCS Signal Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe ADV151-E00 S2 is configured for discrete field signal acquisition rather than analog measurement loops. The module accepts 24 V DC ON\/OFF states from external devices including pushbuttons, selector switches, limit switches, and relay contacts. Electrical isolation is provided between field inputs and the internal control processing path, allowing the acquired status data to be transferred through the CENTUM FIO system bus.\u003c\/p\u003e\n\u003cp\u003eThe module processes input state detection and pushbutton edge counting functions. Each input channel operates within the defined voltage detection range and transfers logic information to the DCS controller through the Yokogawa I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ADV151-E00 S2 support hot-swapping during system operation?\u003cbr\u003eA: The supplied technical data does not specify hot-swap capability. Installation and replacement procedures should follow the Yokogawa CENTUM FIO hardware maintenance instructions.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum internal current consumption of the module?\u003cbr\u003eA: The module requires a maximum internal current consumption of 500 mA at 5 V DC.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module operate in a redundant configuration?\u003cbr\u003eA: The supplied specifications indicate support for dual-redundant configuration within compatible Yokogawa DCS architectures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in the designated Yokogawa FIO enclosure slot according to the system hardware configuration.\u003c\/li\u003e\n\u003cli\u003eVerify that the field input wiring matches the 24 V DC sink\/source signal requirements before connection.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between digital signal wiring and high-voltage power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the site grounding standard and avoid multiple grounding points on shielded signal lines.\u003c\/li\u003e\n\u003cli\u003eConfirm input polarity, common grouping, and terminal assignment before energizing field circuits.\u003c\/li\u003e\n\u003cli\u003eCheck the 24 V DC field supply level before applying input signals to the module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43657670000707,"sku":"ADV151-E00 S2","price":234.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/ADV151-E60.png?v=1741329737","url":"https:\/\/www.plcdcspro.com\/th\/products\/yokogawa-adv151-e00-s2-digital-input-module","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}