{"product_id":"honeywell-tk-idd321-32-point-24vdc-digital-input","title":"Honeywell TK-IDD321 32-Point 24VDC Digital Input","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell TK-IDD321 is a 32-point, 24VDC discrete input module for the Experion Series A control platform. It collects digital status signals from field devices such as switches, contacts and industrial sensors, providing discrete process information to the controller. The input circuits are arranged in two groups of 16 points sharing a common connection. The TK version features conformal coating for industrial control applications.\u003c\/p\u003e\n\u003ch3\u003eCore Specs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Honeywell\u003c\/li\u003e\n\u003cli\u003eModel: TK-IDD321\u003c\/li\u003e\n\u003cli\u003eProduct Type: 24VDC Discrete Input Module\u003c\/li\u003e\n\u003cli\u003ePlatform: Experion Series A \/ C200 I\/O\u003c\/li\u003e\n\u003cli\u003eNumber of Inputs: 32 points\u003c\/li\u003e\n\u003cli\u003eInput Configuration: 2 groups of 16 points per common\u003c\/li\u003e\n\u003cli\u003eNominal Input Voltage: 24 VDC\u003c\/li\u003e\n\u003cli\u003eOn-State Voltage Range: 10–31.2 VDC at 60°C, all channels\u003c\/li\u003e\n\u003cli\u003eMinimum On-State Current: 2 mA\u003c\/li\u003e\n\u003cli\u003eMaximum Off-State Voltage: 5 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum Off-State Current: 1.5 mA\u003c\/li\u003e\n\u003cli\u003eInput Compatibility: IEC Type 1+\u003c\/li\u003e\n\u003cli\u003eProgrammable Input Filter: 0, 1 or 2 ms for off-to-on; 0, 1, 2, 9 or 18 ms for on-to-off\u003c\/li\u003e\n\u003cli\u003eMaximum Power Dissipation: 6.1 W\u003c\/li\u003e\n\u003cli\u003eShort-Circuit \/ Inrush Current: 250 mA peak\u003c\/li\u003e\n\u003cli\u003eIsolation Test: 1500 VDC for 1 second, channel-to-channel and user-to-system\u003c\/li\u003e\n\u003cli\u003eTerminal Block: TC-TBCH, 36-position\u003c\/li\u003e\n\u003cli\u003eConstruction: Conformally coated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHighlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 32 discrete input points for high-density field signal acquisition\u003c\/li\u003e\n\u003cli\u003eUses a 24VDC nominal input interface for industrial switching devices\u003c\/li\u003e\n\u003cli\u003eTwo 16-point input groups simplify field wiring organization\u003c\/li\u003e\n\u003cli\u003eProgrammable input filtering supports different signal response requirements\u003c\/li\u003e\n\u003cli\u003eIsolation testing is specified for both channel-to-channel and user-to-system circuits\u003c\/li\u003e\n\u003cli\u003eConformal coating distinguishes the TK hardware version from its uncoated TC counterpart\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow many digital inputs are available?\u003c\/strong\u003e\u003cbr\u003eThe TK-IDD321 provides 32 discrete input points arranged in two groups of 16.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the nominal input voltage?\u003c\/strong\u003e\u003cbr\u003eThe nominal input voltage is 24 VDC, with an on-state operating range of 10–31.2 VDC at 60°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich terminal block is required?\u003c\/strong\u003e\u003cbr\u003eThe specified terminal block is the 36-position TC-TBCH.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between TK-IDD321 and TC-IDD321?\u003c\/strong\u003e\u003cbr\u003eBoth are identified as the same 32-point, 24VDC input module family. The TK designation indicates conformal coating, while the TC version is uncoated.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the chassis type and module compatibility.\u003c\/li\u003e\n\u003cli\u003ePrepare the TC-TBCH 36-position terminal block.\u003c\/li\u003e\n\u003cli\u003eIdentify the two 16-point input groups and their common connections.\u003c\/li\u003e\n\u003cli\u003eWire field switches and sensors according to the official terminal assignment diagram.\u003c\/li\u003e\n\u003cli\u003eConfigure the required input filter times in the control system.\u003c\/li\u003e\n\u003cli\u003eVerify input status and signal response before returning the system to service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSelection Tips\u003c\/h3\u003e\n\u003cp\u003eSelect TK-IDD321 when the application requires 32 discrete 24VDC input points in an Experion Series A configuration. Do not confuse it with TK-IDJ161, which provides 16 isolated DC input points, or TK-IDX161, which provides 16 diagnostic DC input points. Check the common-group wiring and terminal block requirements before replacement.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":68011409604675,"sku":"TK-IDD321","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/TK-IDD321_4_r180.png?v=1795066811","url":"https:\/\/www.plcdcspro.com\/th\/products\/honeywell-tk-idd321-32-point-24vdc-digital-input","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}