{"product_id":"9907-173-woodward-rev-b-module-load-sharing-120-volt","title":"9907-173 | Woodward REV B Module Load Sharing 120 Volt","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-173\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eload sharing module manages generator load distribution across multiple engines within industrial power generation systems.\u003cbr\u003eWoodward designed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-173\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor precise load balancing, therefore operators maintain stable frequency and voltage under varying electrical demand.\u003c\/p\u003e\n\u003cp\u003eAdditionally,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-173\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates with Woodward generator control platforms and improves synchronization across parallel generator sets.\u003cbr\u003eEngineers frequently install\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-173\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein marine power systems, diesel generator plants, and industrial standby power stations.\u003c\/p\u003e\n\u003cp\u003eFurthermore,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-173\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocesses generator load signals and coordinates governor responses, which ensures accurate real-time load sharing performance.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9907-173\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Revision\u003c\/td\u003e\n\u003ctd\u003eREV B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLoad Sharing Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGenerator load sharing and parallel generator control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Control Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e100–130 VAC control input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Function\u003c\/td\u003e\n\u003ctd\u003eGenerator load signal distribution and governor control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial terminal block wiring connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Inputs\u003c\/td\u003e\n\u003ctd\u003eLoad reference signals and generator feedback inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Outputs\u003c\/td\u003e\n\u003ctd\u003eLoad share control signal outputs for generator governors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Generator Support\u003c\/td\u003e\n\u003ctd\u003eDesigned for multi-generator load balancing systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Components\u003c\/td\u003e\n\u003ctd\u003eSignal conditioning circuits, load control amplifiers, and protective filtering circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Method\u003c\/td\u003e\n\u003ctd\u003eAnalog control interface between generators and governors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Design\u003c\/td\u003e\n\u003ctd\u003eIndustrial multilayer printed circuit board with reinforced connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eControl cabinet panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eIndustrial metal enclosure for electromagnetic shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 24 cm × 16 cm × 5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C industrial cabinet operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Applications\u003c\/td\u003e\n\u003ctd\u003eDiesel generator plants, marine power systems, turbine generator control panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the\u003cspan\u003e \u003c\/span\u003e9907-173\u003cspan\u003e \u003c\/span\u003emodule new or refurbished?\u003c\/strong\u003e\u003cbr\u003eWe supply\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-173\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebrand new original factory equipment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith secure packaging and strict quality inspection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What voltage rating does\u003cspan\u003e \u003c\/span\u003e9907-173\u003cspan\u003e \u003c\/span\u003esupport?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-173\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eload sharing module operates with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e120 VAC control voltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein industrial generator control circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What systems typically use\u003cspan\u003e \u003c\/span\u003e9907-173?\u003c\/strong\u003e\u003cbr\u003eEngineers commonly install\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-173\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eparallel generator control systems, marine power units, and industrial standby generators\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: When will you ship the\u003cspan\u003e \u003c\/span\u003e9907-173\u003cspan\u003e \u003c\/span\u003emodule after ordering?\u003c\/strong\u003e\u003cbr\u003eWe typically ship\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-173\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3 days to 2 weeks\u003c\/strong\u003e, depending on order quantity and warehouse scheduling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Which logistics carriers deliver the product?\u003c\/strong\u003e\u003cbr\u003eWe commonly use international carriers such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDHL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto deliver\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-173\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafely and quickly worldwide.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003csection\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall within Woodward control racks or cabinets\u003c\/li\u003e\n\u003cli\u003eConnect directly to magnetic pickup sensors near turbine or engine shafts\u003c\/li\u003e\n\u003cli\u003eUse proper wiring and shielding to prevent electrical noise interference\u003c\/li\u003e\n\u003cli\u003eCalibration and verification of MPU signals may be required during commissioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43029993881667,"sku":"9907-173","price":234.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/9907-173WoodwardREVBModuleLoadSharing120Volt_2.jpg?v=1773107699","url":"https:\/\/www.plcdcspro.com\/th\/products\/9907-173-woodward-rev-b-module-load-sharing-120-volt","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}