{"product_id":"9907-166m-woodward-digital-turbine-control","title":"9907-166M | Woodward Digital Turbine Control","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-166M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers precise digital control for industrial steam and gas turbine systems.\u003cbr\u003eThis\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward Digital Turbine Control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebelongs to the proven\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e505 Series\u003c\/strong\u003e, widely used in critical power applications.\u003c\/p\u003e\n\u003cp\u003eMoreover, the controller manages speed, load, and sequencing through high-resolution digital processing architecture.\u003cbr\u003eTherefore, operators achieve stable turbine operation, fast response, and repeatable performance across varying loads.\u003c\/p\u003e\n\u003cp\u003eIn addition,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigns the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-166M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor long-term reliability in harsh industrial environments.\u003cbr\u003eAs a result, power plants and process industries trust this controller for continuous-duty turbine regulation.\u003c\/p\u003e\n\u003csection\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9907-166M\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Turbine Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eWoodward 505 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e18–32 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 15 W during normal operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003ePower Protection\u003c\/td\u003e\n\u003ctd\u003eBuilt-in reverse polarity and overvoltage protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eEnergy Storage\u003c\/td\u003e\n\u003ctd\u003eInternal non-volatile memory for configuration and event data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eData Retention\u003c\/td\u003e\n\u003ctd\u003eMaintains stored parameters without external power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade metal housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003eApprox. 222 mm × 286 mm × 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eDimensions (inches)\u003c\/td\u003e\n\u003ctd\u003eApprox. 8.75 in × 11.25 in × 6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 4.5 kg (10 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eEnvironmental Design\u003c\/td\u003e\n\u003ctd\u003eResistant to vibration and electrical noise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8 configurable analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eAnalog Signal Types\u003c\/td\u003e\n\u003ctd\u003eSupports standard industrial voltage and current signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eSpeed Inputs\u003c\/td\u003e\n\u003ctd\u003e2 dedicated high-speed turbine speed input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e16 opto-isolated digital input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 high-resolution analog output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Function\u003c\/td\u003e\n\u003ctd\u003eActuator positioning and control command output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e8 relay-based digital output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eDiscrete Output Use\u003c\/td\u003e\n\u003ctd\u003eAlarms, trips, and system interlocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eSerial Interfaces\u003c\/td\u003e\n\u003ctd\u003eRS-232 and RS-422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eModbus-compatible communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eConfiguration Method\u003c\/td\u003e\n\u003ctd\u003eLocal or remote configuration via serial interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Functions\u003c\/td\u003e\n\u003ctd\u003eSpeed Control Modes\u003c\/td\u003e\n\u003ctd\u003eIsochronous and droop speed control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Functions\u003c\/td\u003e\n\u003ctd\u003eLoad Control\u003c\/td\u003e\n\u003ctd\u003ePrecise turbine load regulation and sharing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Functions\u003c\/td\u003e\n\u003ctd\u003eSequencing\u003c\/td\u003e\n\u003ctd\u003eIntegrated turbine start-up and shutdown sequencing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Functions\u003c\/td\u003e\n\u003ctd\u003eSystem Integration\u003c\/td\u003e\n\u003ctd\u003eInterfaces with actuators, governors, and protection systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplications\u003c\/td\u003e\n\u003ctd\u003eSupported Turbines\u003c\/td\u003e\n\u003ctd\u003eSteam turbines and gas turbines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplications\u003c\/td\u003e\n\u003ctd\u003eTypical Industries\u003c\/td\u003e\n\u003ctd\u003ePower generation, cogeneration, oil \u0026amp; gas, process industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplications\u003c\/td\u003e\n\u003ctd\u003eRetrofit Capability\u003c\/td\u003e\n\u003ctd\u003eSuitable for replacing legacy analog turbine governors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the 9907-166M a brand-new original Woodward product?\u003c\/strong\u003e\u003cbr\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-166M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eships as a brand-new, factory-original\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eturbine control unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Do you keep the 9907-166M in stock?\u003c\/strong\u003e\u003cbr\u003eYes, we maintain ready stock for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-166M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto support urgent project requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How fast do you ship after ordering?\u003c\/strong\u003e\u003cbr\u003eWe ship within 3 days to 2 weeks, depending on order quantity and logistics arrangements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Which logistics providers do you use for delivery?\u003c\/strong\u003e\u003cbr\u003eWe typically ship using DHL and other major international express carriers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What is your return policy if quality issues occur?\u003c\/strong\u003e\u003cbr\u003eWe support returns within 30 days if any verified quality issue appears.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: Can the 9907-166M integrate with existing DCS systems?\u003c\/strong\u003e\u003cbr\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-166M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports serial communication and Modbus-compatible protocols for DCS connectivity.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall within Woodward control racks or cabinets\u003c\/li\u003e\n\u003cli\u003eConnect directly to magnetic pickup sensors near turbine or engine shafts\u003c\/li\u003e\n\u003cli\u003eUse proper wiring and shielding to prevent electrical noise interference\u003c\/li\u003e\n\u003cli\u003eCalibration and verification of MPU signals may be required during commissioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":42932329742403,"sku":"9907-166M","price":234.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/9907-166MWoodwardDigitalTurbineControl_1.jpg?v=1770086785","url":"https:\/\/www.plcdcspro.com\/th\/products\/9907-166m-woodward-digital-turbine-control","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}