{"product_id":"9905-148-woodward-load-sharing-module","title":"9905-148 | Woodward Load Sharing Module","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-148\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides precise real power load sharing for multi-generator systems.\u003cbr\u003eThis\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward Load Sharing Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a dedicated accessory within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2301A Series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol architecture.\u003c\/p\u003e\n\u003cp\u003eMoreover, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-148\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebalances generator load signals through analog summing and sharing circuits.\u003cbr\u003eTherefore, parallel generators maintain stable operation without hunting or uneven load distribution.\u003c\/p\u003e\n\u003cp\u003eIn addition,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigns the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-148\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor simple installation in both new and retrofit projects.\u003cbr\u003eAs a result, system integrators achieve reliable load sharing without complex digital configuration.\u003c\/p\u003e\n\u003csection\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9905-148\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eLoad Sharing Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eCompatible Series\u003c\/td\u003e\n\u003ctd\u003eWoodward 2301A Electronic Load Sharing and Speed Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e±12 VDC supplied from connected controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eVery low power draw from control system supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eEnergy Storage\u003c\/td\u003e\n\u003ctd\u003eNo internal energy storage components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eAnalog load sharing signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eCompact industrial-grade metal housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted or enclosure-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 102 mm × 76 mm × 38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eDimensions (inches)\u003c\/td\u003e\n\u003ctd\u003eApprox. 4.0 in × 3.0 in × 1.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.3 kg (0.66 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd\u003eLoad Sharing Ports\u003c\/td\u003e\n\u003ctd\u003eMultiple analog terminals for inter-module connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eScrew-type industrial terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003eDetermined by system wiring and installation layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Capacity\u003c\/td\u003e\n\u003ctd\u003eSupported Units\u003c\/td\u003e\n\u003ctd\u003eSupports parallel operation of multiple generators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eDesigned for industrial control panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplications\u003c\/td\u003e\n\u003ctd\u003eGenerator Types\u003c\/td\u003e\n\u003ctd\u003eDiesel and gas engine generator sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplications\u003c\/td\u003e\n\u003ctd\u003eTypical Use\u003c\/td\u003e\n\u003ctd\u003eIndustrial power, standby power, and marine systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the 9905-148 brand-new and original from Woodward?\u003c\/strong\u003e\u003cbr\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-148\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eships as a brand-new, factory-original\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eload sharing module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Do you have the 9905-148 in stock?\u003c\/strong\u003e\u003cbr\u003eYes, we keep the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-148\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein stock for immediate project requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How fast can you ship after an order is confirmed?\u003c\/strong\u003e\u003cbr\u003eWe ship within 3 days to 2 weeks, depending on order size and logistics arrangements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Which shipping carriers do you usually use?\u003c\/strong\u003e\u003cbr\u003eWe commonly use DHL and other major international express logistics providers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What if the 9905-148 has a quality problem after delivery?\u003c\/strong\u003e\u003cbr\u003eWe support returns within 30 days if any verified quality issue occurs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: Can the 9905-148 work without a 2301A speed controller?\u003c\/strong\u003e\u003cbr\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-148\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates specifically with compatible\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 2301A Series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrollers.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall within Woodward control racks or cabinets\u003c\/li\u003e\n\u003cli\u003eConnect directly to magnetic pickup sensors near turbine or engine shafts\u003c\/li\u003e\n\u003cli\u003eUse proper wiring and shielding to prevent electrical noise interference\u003c\/li\u003e\n\u003cli\u003eCalibration and verification of MPU signals may be required during commissioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":42932339638339,"sku":"9905-148","price":234.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/9905-148WoodwardLoadSharingModule_1.jpg?v=1770088560","url":"https:\/\/www.plcdcspro.com\/th\/products\/9905-148-woodward-load-sharing-module","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}