{"product_id":"5410-995-woodward-integrated-circuit-rtd","title":"5410-995 | Woodward Integrated Circuit, RTD","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Woodward 5410-995 Integrated Circuit RTD module provides accurate temperature signal processing for demanding industrial control systems.\u003cbr\u003eIt is designed to interface directly with RTD sensors, ensuring stable, repeatable temperature measurements in critical machinery environments.\u003cbr\u003eMoreover, this module supports precise thermal monitoring required for turbine control, engine management, and process automation applications.\u003c\/p\u003e\n\u003cp\u003eEngineers rely on the 5410-995 for its consistent signal integrity and proven compatibility with Woodward control platforms.\u003cbr\u003eTherefore, it plays a key role in protecting equipment, optimizing performance, and supporting predictive maintenance strategies.\u003c\/p\u003e\n\u003csection\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e5410-995\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIntegrated Circuit RTD Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eRTD temperature signal conditioning and processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eApplication Role\u003c\/td\u003e\n\u003ctd\u003eTemperature input interface for control systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Characteristics\u003c\/td\u003e\n\u003ctd\u003eSupported Sensor Types\u003c\/td\u003e\n\u003ctd\u003eRTD sensors (Pt100 \/ industrial RTD standards)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Characteristics\u003c\/td\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eResistance-based temperature conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Characteristics\u003c\/td\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle-channel RTD input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Characteristics\u003c\/td\u003e\n\u003ctd\u003eSensor Excitation\u003c\/td\u003e\n\u003ctd\u003eInternal precision excitation source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Characteristics\u003c\/td\u003e\n\u003ctd\u003eLead Compensation\u003c\/td\u003e\n\u003ctd\u003eSupported for improved measurement accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eSignal Conditioning\u003c\/td\u003e\n\u003ctd\u003ePrecision analog signal amplification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003eHigh linearity across operating temperature range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eNoise Immunity\u003c\/td\u003e\n\u003ctd\u003eHigh resistance to EMI and electrical interference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eDrift Performance\u003c\/td\u003e\n\u003ctd\u003eLow thermal and long-term drift\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance\u003c\/td\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003eDesigned for high-accuracy temperature monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance\u003c\/td\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eOptimized for real-time control feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance\u003c\/td\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003eStable output under continuous operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003ePower Supply Type\u003c\/td\u003e\n\u003ctd\u003eSupplied through control system backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLow power integrated circuit design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eDesigned to reduce ground loop interference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003eSuitable for industrial control environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade storage conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eDesigned for non-condensing environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eIntegrated within Woodward control hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eCompact IC-based module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003ePlug-in integration with compatible systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eWoodward turbine and engine control platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eInternal system signal interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReliability\u003c\/td\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003eContinuous-duty industrial operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReliability\u003c\/td\u003e\n\u003ctd\u003eDesign Life\u003c\/td\u003e\n\u003ctd\u003eIntended for long-term system deployment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eQuality Standard\u003c\/td\u003e\n\u003ctd\u003eManufactured to Woodward industrial quality standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003eQ1: What type of sensors does the Woodward 5410-995 support?\u003cbr\u003eA1: The module is designed specifically for RTD temperature sensors used in industrial control systems.\u003c\/p\u003e\n\u003cp\u003eQ2: Is the 5410-995 compatible with existing Woodward control platforms?\u003cbr\u003eA2: Yes, it integrates seamlessly with Woodward control and monitoring systems.\u003c\/p\u003e\n\u003cp\u003eQ3: Can this module be used in continuous-operation environments?\u003cbr\u003eA3: Yes, it is engineered for continuous-duty industrial applications with high reliability requirements.\u003c\/p\u003e\n\u003cp\u003eQ4: What are the main benefits of using this RTD module?\u003cbr\u003eA4: It provides stable temperature measurement, reduced signal noise, and improved long-term accuracy.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall within Woodward control racks or cabinets\u003c\/li\u003e\n\u003cli\u003eConnect directly to magnetic pickup sensors near turbine or engine shafts\u003c\/li\u003e\n\u003cli\u003eUse proper wiring and shielding to prevent electrical noise interference\u003c\/li\u003e\n\u003cli\u003eCalibration and verification of MPU signals may be required during commissioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":42929776459843,"sku":"5410-995","price":234.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/5410-995WoodwardIntegratedCircuit_RTD_1.jpg?v=1770002489","url":"https:\/\/www.plcdcspro.com\/th\/products\/5410-995-woodward-integrated-circuit-rtd","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}