{"product_id":"yokogawa-sdv541-s23-digital-output-module-16-channel","title":"Yokogawa SDV541-S23 Digital Output Module (16-channel)","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe SDV541 is a 16-channel Digital Output Module designed for industrial applications requiring reliable and isolated 24 V DC outputs. This module supports various configurations with options for explosion protection and different connection interfaces.\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: SDV541\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e: 16-channel, module isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e: 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage Drop\u003c\/strong\u003e: 1 V maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Power Supply\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRating\u003c\/strong\u003e: 24 V DC, 3.4 A minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range\u003c\/strong\u003e: 24 V DC + 20% \/ -10%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Capacity\u003c\/strong\u003e: 3.4 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Format\u003c\/strong\u003e: Current source\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Load Current\u003c\/strong\u003e: 0.2 A per output line, 3.2 A total output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Load Current\u003c\/strong\u003e: 35 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Resistance Range\u003c\/strong\u003e: 120 to 685 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Response Time\u003c\/strong\u003e: 30 ms maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Leak Current at Output Off\u003c\/strong\u003e: 1.6 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstand Voltage\u003c\/strong\u003e: 2 kV AC between output signal lines and system, for 1 minute with 16-point input lines collectively connected (negative lines)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 V DC\u003c\/strong\u003e: 300 mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 V DC\u003c\/strong\u003e: 150 mA maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eApprox. 0.29 kg (For pressure clamp terminal block or MIL cable)\u003c\/li\u003e\n\u003cli\u003eApprox. 0.31 kg (With dedicated signal cable interface adapter)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Connection Options\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePressure clamp terminal\u003c\/li\u003e\n\u003cli\u003eMIL cable\u003c\/li\u003e\n\u003cli\u003eDedicated signal cable (AKB331, AKB651)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSuffix Codes for Variants\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-S\u003c\/strong\u003e: Standard type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5\u003c\/strong\u003e: For pressure clamp terminal block or MIL cable, no explosion protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6\u003c\/strong\u003e: With signal cable interface adapter, no explosion protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE\u003c\/strong\u003e: For pressure clamp terminal block or MIL cable, with explosion protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF\u003c\/strong\u003e: With signal cable interface adapter, with explosion protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\u003c\/strong\u003e: With ISA Standard G3, temperature range of -20 to 70 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC\u003c\/strong\u003e: With ISA Standard G3, high-density installation, temperature range of -20 to 70 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":41762069151811,"sku":"SDV541-S23","price":345.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/SDV541-S23.png?v=1741330388","url":"https:\/\/www.plcdcspro.com\/products\/yokogawa-sdv541-s23-digital-output-module-16-channel","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}