{"product_id":"mtl-8104-ao-ip-03-analog-output-module-for-pac8000","title":"MTL 8104-AO-IP-03 Analog Output Module for PAC8000","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eMTL 8104-AO-IP-03\u003c\/strong\u003e is an 8-channel analog output module for the PAC8000 I\/O system. It delivers precise 4–20 mA signals to field devices such as actuators, I\/P converters, and control valves. Engineered for general-purpose and hazardous-area installations, it supports non-incendive field circuits and complies with FM, ATEX, and IECEx standards.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 8 single-ended analog outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Range:\u003c\/strong\u003e 4–20 mA nominal (1–23 mA full range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 12-bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.25% of span\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e ≤25 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Circuit Detection:\u003c\/strong\u003e 0.7 ± 0.25 mA per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Compliance:\u003c\/strong\u003e 20 mA at 21.6 V DC into 700 Ω load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eChannel to Railbus: 100 V AC\u003c\/li\u003e\n\u003cli\u003eNo channel-to-channel isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 V DC ±10% (bussed field power)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRailbus Current:\u003c\/strong\u003e 100 mA typical, 150 mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Power Consumption:\u003c\/strong\u003e 300 mA max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e –20°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Width:\u003c\/strong\u003e 42 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 200 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Key Code:\u003c\/strong\u003e A4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e FM non-incendive field wiring parameters (Voc = 28.7 V, Isc = 33 mA, Ca = 0.17 µF, La = 11.0 mH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e FM, ATEX, IECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount on PAC8000 carrier using DIN rail or flat panel\u003c\/li\u003e\n\u003cli\u003eUse approved field terminals:\n\u003cul\u003e\n\u003cli\u003eGeneral Purpose: 8602-FT-ST, 8604-FT-FU\u003c\/li\u003e\n\u003cli\u003eHazardous Area: 8601-FT-NI, 8603-FT-FU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding and shielding of analog signal cables\u003c\/li\u003e\n\u003cli\u003eFollow SCI control drawings for spacing and segregation\u003c\/li\u003e\n\u003cli\u003eConfigure channel status and fail-safe parameters via system software\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MTL","offers":[{"title":"Default Title","offer_id":42529530183747,"sku":"8104-AO-IP-03","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/8104-AO-IP-03_3.png?v=1756197644","url":"https:\/\/www.plcdcspro.com\/products\/mtl-8104-ao-ip-03-analog-output-module-for-pac8000","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}