{"product_id":"honeywell-mu-taih23-enhanced-power-high-level-analog-input-fta-card","title":"Honeywell MU-TAIH23 Enhanced Power High Level Analog Input FTA Card","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MU-TAIH23\u003c\/strong\u003e is an Enhanced Power High-Level Analog Input Field Termination Assembly (FTA) designed for use with 16 differential input channels. It supports voltage and current signals from 2-wire or self-powered transmitters and is CE Mark certified. The FTA provides high accuracy, reliable input conditioning, and robust safety features for industrial automation applications, including hazardous environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Differential Input Channels\u003c\/strong\u003e: Supports voltage and current signals, including 4-20 mA and various voltage ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy\u003c\/strong\u003e: Provides precise signal processing with a resolution of 16 bits (14 bits used) and a hardware accuracy of ±0.075% full-scale at 23.5°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Power Conditioning\u003c\/strong\u003e: Individually protected current-limiting circuits for transmitter power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Isolation and Protection\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eCommon mode rejection: 70 dB.\u003c\/li\u003e\n\u003cli\u003eNormal mode rejection: 32 dB at 60 Hz.\u003c\/li\u003e\n\u003cli\u003eSurge withstand capability: ANSI\/IEEE C37.90.1-1978 compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Input Impedance\u003c\/strong\u003e: Voltage input impedance \u0026gt; 10 MΩ for accurate signal acquisition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Input Scanning\u003c\/strong\u003e: 4 samples per second per channel with all channels sampled within 250 ms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eInput Parameters\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Types\u003c\/strong\u003e: Voltage, current (2-wire or self-powered transmitters).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Ranges\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eVoltage: 0 to 5 V, 1 to 5 V, 0.4 to 2 V.\u003c\/li\u003e\n\u003cli\u003eCurrent: 4-20 mA (via 250 Ω resistor).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance\u003c\/strong\u003e: \u0026gt; 10 MΩ (powered).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Input Voltage\u003c\/strong\u003e: ±30 V (no damage).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e: -6 to +5 V peak.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Rejection Ratio\u003c\/strong\u003e: 70 dB (dc to 60 Hz, 500 Ω source imbalance).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal Mode Rejection Ratio\u003c\/strong\u003e: 32 dB at 60 Hz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution\u003c\/strong\u003e: 16 bits (14 bits used).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e±0.075% full-scale (23.5°C ±2°C).\u003c\/li\u003e\n\u003cli\u003e±0.15% full-scale (0°C to 50°C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Scan Rate\u003c\/strong\u003e: 4 samples per second per channel; all channels scanned within 250 ms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTransmitter Power Conditioning\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModels Supported\u003c\/strong\u003e: Individually Protected Current Limiting Circuits for Class 1, Div 2 interfacing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e: Minimum 23 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Current\u003c\/strong\u003e: 30 mA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eIsolation \u0026amp; Protection\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Withstand Capability\u003c\/strong\u003e: ANSI\/IEEE C37.90.1-1978.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Normal Mode Input\u003c\/strong\u003e: ±30 V (no damage).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrosstalk\u003c\/strong\u003e: 60 dB (dc to 60 Hz, channel-to-channel).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0°C to 50°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy Deviation\u003c\/strong\u003e: ±0.15% full-scale across the operating range.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42031471362115,"sku":"MU-TAIH23","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/MU-TAIH02_51304453-100_2.png?v=1741329221","url":"https:\/\/www.plcdcspro.com\/products\/honeywell-mu-taih23-enhanced-power-high-level-analog-input-fta-card","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}