{"product_id":"general-electric-ge-g60e00hch-multilin-g60-generator-protection-system","title":"General Electric GE G60E00HCH Multilin G60 Generator Protection System","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe GE Multilin G60 protects generators with advanced monitoring and control.\u003cbr\u003eIt ensures system stability and generator reliability.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOrdering Code Structure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe G60 model number follows this format:\u003cbr\u003e\u003cstrong\u003eG60 - * ** - H * * - F\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e- H** - M** - P** - U** - W***\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBase Unit \u0026amp; CPU Options\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSelect the communication setup that meets your system requirements:\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003eRS485 \u0026amp; RS485 (no IEC 61850)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eRS485 + Multimode ST 100BaseFX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003eRS485 + Multimode ST Redundant 100BaseFX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eRS485 + 10\/100 100BaseT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eRS485 + 3x Multimode SFP LC 100BaseFX (FW v7xx+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eU\u003c\/td\u003e\n\u003ctd\u003eRS485 + 2x Multimode SFP LC 100BaseFX + 1x SFP RJ45 100BaseT (FW v7xx+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV\u003c\/td\u003e\n\u003ctd\u003eRS485 + 3x SFP RJ45 100BaseT (FW v7xx+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eW\u003c\/td\u003e\n\u003ctd\u003eRS485 + 2x 100BaseFX Multimode ST + 1x 10\/100BaseT RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSoftware Options\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eChoose software features to improve communication and functionality:\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eEthernet Global Data (EGD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eIEC 61850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eEGD + IEC 61850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA0\u003c\/td\u003e\n\u003ctd\u003eCyberSentry UR Level 1 (FW 7.xx+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB0\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588 (FW 7.xx+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC0\u003c\/td\u003e\n\u003ctd\u003ePRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD0\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588 + CyberSentry (FW 7.xx+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDecide on mounting style depending on your environment:\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003eHorizontal (19” rack) Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eHorizontal - Harsh Chemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV\u003c\/td\u003e\n\u003ctd\u003eVertical (3\/4 size) Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eVertical - Harsh Chemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eUser Interface Options\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSelect display language and panel type:\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003e7\" Graphical, USB, Multi-Language (FW 7.6x+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003ctd\u003eVertical Front, English\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI-T\u003c\/td\u003e\n\u003ctd\u003eEnhanced Front Panels (Various Languages)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply Options\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003ePick a suitable power supply type:\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003e125\/250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRH\u003c\/td\u003e\n\u003ctd\u003eRedundant 125\/250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003e24-48 V DC Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCT\/VT DSP Options\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSelect the CT\/VT input configuration:\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e8L\u003c\/td\u003e\n\u003ctd\u003e4CT\/4VT, enhanced diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8M\u003c\/td\u003e\n\u003ctd\u003eSensitive Ground 4CT\/4VT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8N\u003c\/td\u003e\n\u003ctd\u003e8CT, enhanced diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8R\u003c\/td\u003e\n\u003ctd\u003eSensitive Ground 2CT\/6VT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIEC 61850 Process Bus\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eChoose process bus module if required:\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e81\u003c\/td\u003e\n\u003ctd\u003e8-Port IEC 61850 Process Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003ctd\u003e2x 1000BaseF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e86\u003c\/td\u003e\n\u003ctd\u003e4x 1000BaseF + 4x 100BaseFX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003ctd\u003e4x 100BaseFX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDigital I\/O Options\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eConfigure Digital I\/O as needed for the application.\u003cbr\u003eMany options include Form-A, Form-C, Fast Form-C, Digital Inputs.\u003cbr\u003e(Full list available upon request.)\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTransducer I\/O Options\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eChoose the right transducer inputs:\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5A\u003c\/td\u003e\n\u003ctd\u003e4 DCmA Inputs, 4 DCmA Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5C\u003c\/td\u003e\n\u003ctd\u003e8 RTD Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5E\u003c\/td\u003e\n\u003ctd\u003e4 DCmA Inputs, 4 RTD Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5F\u003c\/td\u003e\n\u003ctd\u003e8 DCmA Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInter-Relay Communication Options\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSelect relay communication method:\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e7A-7W\u003c\/td\u003e\n\u003ctd\u003eFiber, G.703, RS422, IEEE C37.94 (1 or 2 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eExample Configuration Explanation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFor model\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG60E00HCH\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCPU: E (RS485 only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSoftware: 00 (None)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMount: H (Horizontal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUser Interface: C (Custom Option)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower: H (125\/250 V AC\/DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":42353520902211,"sku":"G60E00HCH","price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/G60E00HCH.png?v=1749526511","url":"https:\/\/www.plcdcspro.com\/products\/general-electric-ge-g60e00hch-multilin-g60-generator-protection-system","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}