{"product_id":"f3wd64-3p-yokogawa-i-o-module-for-fa-m3","title":"F3WD64-3P | Yokogawa I\/O Module for FA-M3","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa F3WD64-3P is a combined digital input\/output (I\/O) module (sink type) designed for the FA-M3 programmable logic controller (PLC) system. It integrates 32 DC input channels and 32 transistor-sink output channels within a single compact unit, providing efficient control and monitoring for 24 V DC applications. The module includes built-in short-circuit protection and supports configurable input sampling times for flexible system integration.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e F3WD64-3P\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Type:\u003c\/strong\u003e Sink type (combined input\/output)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e 32 (terminals 01–32)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e 32 (terminals 33–64)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Lines:\u003c\/strong\u003e 8 points per common for both input and output blocks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Input Voltage:\u003c\/strong\u003e 24 V DC (20.4–26.4 V DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current (Rated):\u003c\/strong\u003e 4.1 mA per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput ON\/OFF Threshold:\u003c\/strong\u003e ON ≥ 16 V DC \u0026amp; ≥ 3.2 mA; OFF ≤ 5.8 V DC \u0026amp; ≤ 0.9 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Sampling Time Options:\u003c\/strong\u003e Always (0 μs), 62.5 μs, 250 μs, or 1 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Simultaneous ON Ratio (Inputs):\u003c\/strong\u003e 60% of input points active simultaneously\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Transistor contact (sink)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Output Load Voltage:\u003c\/strong\u003e 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Load Current:\u003c\/strong\u003e 0.1 A per point; 0.4 A per common line\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time (Output):\u003c\/strong\u003e OFF → ON: max 1 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Features:\u003c\/strong\u003e Short-circuit protection, overheat protection, active clamp circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower for Outputs:\u003c\/strong\u003e 24 V DC, 55 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWithstand Voltage (Isolation):\u003c\/strong\u003e 1500 V AC, 1 min (external terminals to internal circuit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption (5 V Bus):\u003c\/strong\u003e 170 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Connections:\u003c\/strong\u003e Two 40-pin connectors for backplane interface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 120 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0–55 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e –20 to +75 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 10–90% RH (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module on the FA-M3 backplane using the provided 40-pin connectors\u003c\/li\u003e\n\u003cli\u003eUse appropriate wiring and follow 8-point common line grouping for I\/O terminals\u003c\/li\u003e\n\u003cli\u003eEnsure power supply capacity supports 55 mA auxiliary load current\u003c\/li\u003e\n\u003cli\u003eMaintain an ambient temperature range of 0–55 °C and avoid condensation\u003c\/li\u003e\n\u003cli\u003eMonitor output status through diagnostic indicators or PLC logic supervision\u003c\/li\u003e\n\u003cli\u003eObserve correct wiring polarity and do not exceed rated per-point or per-common current limits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":42624238026819,"sku":"F3WD64-3P","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/F3WD64-3P.png?v=1760163816","url":"https:\/\/www.plcdcspro.com\/products\/f3wd64-3p-yokogawa-i-o-module-for-fa-m3","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}