{"product_id":"emerson-charm-digital-output-deltav-series-kl3002x1-ba1","title":"Emerson Charm Digital Output Deltav Series KL3002X1-BA1","description":"\u003ch3 class=\"\"\u003e\u003cstrong\u003eKL3002X1-BA1 DO 24 VDC High Side CHARM\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 class=\"\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp class=\"\"\u003eThe KL3002X1-BA1 is a 24 VDC high-side digital output module from Phoenix Contact's CHARMs (Customizable Hardware for Automation with Real-Time Monitoring) series. It is designed for use in hazardous environments, with certifications for operation in Class I Div. 2 and Zone 2 areas. This module allows the control of digital outputs with robust protection against environmental and electrical disturbances. It’s commonly used in DeltaV™ Electronic Marshalling Systems for automation tasks where safety is critical.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4 class=\"\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKL3002X1-BA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Output (DO), High Side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eCHARM Bus Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e6.3 VDC @ 32 mA\u003cbr\u003e\u003cstrong\u003eField Circuit Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC @ 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII 3G Ex ec IIC Gc, FM19ATEX0173U, IECEx FMG 19.0019U, FM21UKEX0017U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFM17CA0145U, FM17US0286U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eClass I Div. 2 GP. A,B,C,D\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eClass I Zone 2 AEx\/Ex ec IIC Gc\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10g ½ Sinewave for 11ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1mm Peak to Peak from 2 to 13.2Hz; 0.7g from 13.2 to 150Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirborne Contaminants\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04 –1985 Class G3 Airborne Contaminants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95% Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Block Key Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3C (Key Position)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible with DeltaV™ Electronic Marshalling System, CHARMs I\/O Subsystem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation \u0026amp; Safety Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eInstallation Instructions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12P5403 (Zone 2)\u003cbr\u003e\u003cstrong\u003eWarning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSystem power must be off in hazardous areas during insertion\/removal of the module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":42213142757443,"sku":"KL3002X1-BA1","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/KL3002X1-BA1_2.png?v=1744092544","url":"https:\/\/www.plcdcspro.com\/products\/emerson-charm-digital-output-deltav-series-kl3002x1-ba1","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}