{"product_id":"cc-pdis01-honeywell-digital-input-sequence-of-events-disoe","title":"CC-PDIS01 | Honeywell Digital Input Sequence of Events (DISOE)","description":"\u003cp class=\"\"\u003e\u003cstrong\u003eHoneywell CC-PDIS01 Digital Input Sequence of Events (DISOE)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe Digital Input Sequence of Events (DISOE) accepts 24VDC discrete signals as discrete inputs. This module supports 1ms resolution Sequence of Events (SOE) and is designed to provide high-precision event timing for industrial automation systems. It supports three operation modes and includes robust diagnostics for data integrity and fault detection.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Input Sequence of Events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIOTA Models\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC-TDIL01 (Non Redundant 9”), CC-TDIL11 (Redundant 12”), CC-GDIL11 (Redundant 12”), CC-GDIL21 (Non Redundant 6”), CC-GDIL01 (Redundant for exp. 12”), CC-SDXX01 (GI-IS I\/O Expander 12”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channel Scanning (PV)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormal = 20ms; Fast = 5ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Input Resolution (SOE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 VAC RMS or ±1500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Technique\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptical (in IOM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDI Power Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eON Sense Voltage\/Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13 VDC (min) or 3 mA (min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOFF Sense Voltage\/Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VDC (max) or 1.2 mA (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2 KΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAbsolute Delay Across Input Filter and Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ms ± 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Resistance for Guaranteed ON Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 Ω max @ 15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Resistance for Guaranteed OFF Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 KΩ min @ 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModes of Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormal (20ms PV scan), Sequence of Events (1ms resolution SOE, 20ms PV scan), Low Latency (5ms PV scan)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtensive internal diagnostics for data integrity, Open Wire Detection (in Normal mode only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional redundancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Power Selection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal or external field power selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExcitation Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOnboard excitation power (no need for marshalling power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-incendive Field Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupplies non-incendive field power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect \/ Reverse Input Indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42195993788483,"sku":"CC-PDIS01","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/CC-PDIS01.png?v=1743495034","url":"https:\/\/www.plcdcspro.com\/products\/cc-pdis01-honeywell-digital-input-sequence-of-events-disoe","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}