{"product_id":"allen-bradley-thermocouple-analog-input-1756-it16-1756it16-ab-1756-it16-us","title":"Allen Bradley Thermocouple Analog Input 1756-IT16 \/ 1756IT16 AB 1756 IT16 US","description":"\u003ch3 class=\"\"\u003e\u003cstrong\u003eAllen-Bradley 1756-IT16 Thermocouple Analog Input Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe 1756-IT16 is an analog input module from the ControlLogix series by Allen-Bradley \/ Rockwell Automation. It is designed for applications requiring thermocouple inputs, offering 16 non-isolated channels with 24-bit resolution. This module is ideal for advanced control applications, providing excellent performance for temperature sensing and other high-accuracy measurements. The module is designed for installation in a ControlLogix chassis and offers a status LED for operation feedback.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation \/ Allen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\/Catalog No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-IT16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog input, thermocouple mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnhanced I\/O for advanced control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-isolated thermocouple input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-100 to 100 millivolts (mV), max 5 Volt-Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Volts (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw at 5.1V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Draw at 24V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.9 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen-style (No enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlLogix chassis (1756)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±30 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Mode Noise Rejection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 dB at 60 Hertz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCJC Sensors Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (not included, part number 1756-CJC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, c-UL-us, RCM, Ex, KC, EAC, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (for operation feedback)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":42198325067843,"sku":"1756-IT16","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/1756-IT16_2.png?v=1743577288","url":"https:\/\/www.plcdcspro.com\/products\/allen-bradley-thermocouple-analog-input-1756-it16-1756it16-ab-1756-it16-us","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}