{"product_id":"9905-972-woodward-linknet-6-channel-4-20ma-output-module","title":"9905-972 | Woodward LINKNET 6 CHANNEL 4-20mA OutPut MODULE","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-972\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eanalog output module expands control capability inside the Woodward LINKNET distributed control architecture.\u003cbr\u003eWoodward designed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-972\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto deliver accurate 4-20mA analog signals for turbine, compressor, and generator control systems.\u003cbr\u003eEngineers integrate\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-972\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules when industrial control systems require stable current loop outputs for actuators and monitoring equipment.\u003c\/p\u003e\n\u003cp\u003eFurthermore,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-972\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures precise signal conversion while maintaining stable performance under demanding industrial operating conditions.\u003cbr\u003eTherefore automation engineers choose\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-972\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhen reliable analog communication becomes essential for turbine control networks.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9905-972\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eLINKNET Distributed Control Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e6-Channel Analog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA current loop output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e6 independent analog output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Range\u003c\/td\u003e\n\u003ctd\u003e4 mA to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit digital to analog conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Resistance\u003c\/td\u003e\n\u003ctd\u003eUp to 500 Ω typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eElectrically isolated analog channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eLINKNET network interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eWoodward LINKNET distributed control communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLED indicators for module status and communication activity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eProvided through LINKNET system power backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 6–8 W during normal operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003ePassive cooling through system airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eRack or panel mounting within LINKNET system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Dimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 160 mm × 120 mm × 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Weight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Applications\u003c\/td\u003e\n\u003ctd\u003eTurbine control, compressor control, generator automation, industrial process control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-972\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodule new and original?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. Our\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-972\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules are\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% new original factory products\u003c\/strong\u003e, carefully inspected before shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Do you keep the\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-972\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLINKNET module in stock?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. We usually maintain\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-972\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules in stock to ensure fast delivery for industrial customers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How long does delivery usually take after ordering?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOrders normally ship\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewithin 3 days to 2 weeks\u003c\/strong\u003e, depending on order size and warehouse scheduling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Which logistics companies do you use for shipment?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe frequently use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDHL, FedEx, UPS, and other international logistics carriers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto guarantee fast delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What should customers do if the\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-972\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodule has a quality issue?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA5:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCustomers can request\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereturns or replacement within 30 days\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eif any quality issue appears after delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: What equipment uses the\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-972\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog output module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA6:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-972\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule operates inside\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward LINKNET control systems\u003c\/strong\u003e, providing analog outputs for turbine and industrial automation control.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003csection\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall within Woodward control racks or cabinets\u003c\/li\u003e\n\u003cli\u003eConnect directly to magnetic pickup sensors near turbine or engine shafts\u003c\/li\u003e\n\u003cli\u003eUse proper wiring and shielding to prevent electrical noise interference\u003c\/li\u003e\n\u003cli\u003eCalibration and verification of MPU signals may be required during commissioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43030110699587,"sku":"9905-972","price":234.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/9905-972WoodwardLINKNET6CHANNEL4-20mAOutPutMODULE_2.jpg?v=1773110760","url":"https:\/\/www.plcdcspro.com\/products\/9905-972-woodward-linknet-6-channel-4-20ma-output-module","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}