{"product_id":"5417-1251-woodward-dpc-usb-direct-configuration-cable","title":"5417-1251 | Woodward DPC-USB Direct Configuration Cable","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp data-start=\"285\" data-end=\"665\"\u003eThe \u003cstrong data-start=\"289\" data-end=\"302\"\u003e5417-1251\u003c\/strong\u003e DPC-USB cable enables direct configuration between a PC and Woodward controllers.\u003cbr data-start=\"384\" data-end=\"387\"\u003eIt connects a USB host interface to the controller service port through an RJ45 connector.\u003cbr data-start=\"477\" data-end=\"480\"\u003eEngineers use this cable for parameter configuration, firmware updates, and diagnostics.\u003cbr data-start=\"568\" data-end=\"571\"\u003eMoreover, the compact 0.5 meter length ensures stable communication inside control cabinets.\u003c\/p\u003e\n\u003cp data-start=\"667\" data-end=\"916\"\u003eThe \u003cstrong data-start=\"671\" data-end=\"684\"\u003e5417-1251\u003c\/strong\u003e supports Woodward easYgen and LS-5 controller platforms.\u003cbr data-start=\"741\" data-end=\"744\"\u003eIt integrates seamlessly with Woodward ToolKit software for commissioning tasks.\u003cbr data-start=\"824\" data-end=\"827\"\u003eTherefore, technicians complete setup procedures quickly without additional converters.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter Category\u003c\/th\u003e\n\u003cth\u003eSpecification Detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5417-1251\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDPC-USB Direct Configuration Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Connector\u003c\/td\u003e\n\u003ctd\u003eUSB Type-A male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Connector\u003c\/td\u003e\n\u003ctd\u003eRJ45 service port connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.5 m (approx. 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eCAT-5 structured data cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eSpecialized configuration interface (non-standard Ethernet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eIntegrated galvanic isolation between USB and controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Method\u003c\/td\u003e\n\u003ctd\u003eUSB to serial conversion via internal electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Devices\u003c\/td\u003e\n\u003ctd\u003eeasYgen series, LS-5 controllers, compatible Woodward control units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003ePowered via USB host connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade molded connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (Approx.)\u003c\/td\u003e\n\u003ctd\u003e0.3–0.6 kg including packaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eControl cabinet and service environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Application\u003c\/td\u003e\n\u003ctd\u003eController setup, diagnostics, firmware updates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003carticle\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the 5417-1251 function as a normal Ethernet cable?\u003c\/strong\u003e\u003cbr\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5417-1251\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses CAT-5 wiring but provides a specialized configuration interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What cable length does the 5417-1251 provide?\u003c\/strong\u003e\u003cbr\u003eThe cable length measures approximately 0.5 meters for cabinet-level configuration tasks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the 5417-1251 include electrical isolation?\u003c\/strong\u003e\u003cbr\u003eYes, it includes integrated galvanic isolation between the USB and controller sides.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is the product new and available in stock?\u003c\/strong\u003e\u003cbr\u003eYes, we provide brand-new original factory units with available inventory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What shipping and return policies apply?\u003c\/strong\u003e\u003cbr\u003eWe ship within 3 days to 2 weeks, and we support 30-day returns for quality concerns.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003csection\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall within Woodward control racks or cabinets\u003c\/li\u003e\n\u003cli\u003eConnect directly to magnetic pickup sensors near turbine or engine shafts\u003c\/li\u003e\n\u003cli\u003eUse proper wiring and shielding to prevent electrical noise interference\u003c\/li\u003e\n\u003cli\u003eCalibration and verification of MPU signals may be required during commissioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43018965909571,"sku":"5417-1251","price":234.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/5417-1251WoodwardDPC-USBDirectConfigurationCable_1.jpg?v=1772592062","url":"https:\/\/www.plcdcspro.com\/products\/5417-1251-woodward-dpc-usb-direct-configuration-cable","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}