{"product_id":"3bsc610066r1-abb-sd833-power-supply-unit","title":"3BSC610066R1 | ABB SD833 Power Supply Unit","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eABB SD833\u003c\/strong\u003e is a system power supply module used in ABB System 800xA control architectures. It converts AC mains voltage to regulated 24 V DC output, supplying power to AC 800M controllers, communication interfaces, and termination units. The module is designed for DIN rail mounting and supports high-reliability industrial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eProduct ID:\u003c\/strong\u003e 3BSC610066R1\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 100–120 V AC \/ 200–240 V AC (auto-select)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Tolerance:\u003c\/strong\u003e ±10%\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 24 V DC nominal\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eRated Output Current:\u003c\/strong\u003e 10 A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Output Current:\u003c\/strong\u003e 12 A (ambient temperature \u0026lt; 45°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eRated Output Power:\u003c\/strong\u003e 240 W\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency:\u003c\/strong\u003e 91–91.6%\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eRipple (peak-to-peak):\u003c\/strong\u003e \u0026lt; 50 mV\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHold-up Time:\u003c\/strong\u003e 46–47 ms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eOvervoltage Protection:\u003c\/strong\u003e \u0026lt; 39 V\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current:\u003c\/strong\u003e \u0026lt; 10 A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eRecommended External Fuse (primary side):\u003c\/strong\u003e 10–20 A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eShort-Circuit Protection (secondary side):\u003c\/strong\u003e 14–18 A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e 22–24 W\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W × H × D):\u003c\/strong\u003e 60 mm × 124 mm × 117 mm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 700 g\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInstallation Clearance:\u003c\/strong\u003e 15 mm (width), 40 mm (height)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Certification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP20 (IEC 60529)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e 2 (IEC 60664-1)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eCorrosion Protection:\u003c\/strong\u003e ISA-S71.04 Class G2\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to +55°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e –40 to +70°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95%, non-condensing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Safety Standards:\u003c\/strong\u003e IEC 61131-2, UL 508, EN 50178\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e EN 61000-6-4, EN 61000-6-2\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eOvervoltage Category:\u003c\/strong\u003e III (IEC\/EN 60664-1)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Directive 2011\/65\/EU (EN 50581:2012)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eWEEE Compliance:\u003c\/strong\u003e Directive 2012\/19\/EU\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMarine Certification:\u003c\/strong\u003e DNV-GL, ABS\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Location Certification:\u003c\/strong\u003e Not ATEX or IECEx Zone 2 certified\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42600564981827,"sku":"SD833","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/SD833_3.png?v=1759048508","url":"https:\/\/www.plcdcspro.com\/products\/3bsc610066r1-abb-sd833-power-supply-unit","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}