{"product_id":"396509-05-3-emerson-power-supply-module","title":"396509-05-3 | Emerson POWER SUPPLY MODULE","description":"\u003ch2\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"64\" data-end=\"377\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003eEmerson 396509-05-3\u003c\/strong\u003e\u003cspan\u003e is a high-performance \u003c\/span\u003e\u003cstrong\u003ePOWER SUPPLY MODULE\u003c\/strong\u003e\u003cspan\u003e designed for the \u003c\/span\u003e\u003cstrong\u003eControlWave Micro\u003c\/strong\u003e\u003cspan\u003e series. It provides stable and reliable 24 V DC power to automation controllers and modules. This module ensures continuous operation of industrial process control systems while maintaining safety and efficiency. Its compact design and durable construction allow seamless integration into control cabinets or panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e396509-05-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module (ControlWave Micro Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 88% at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple \u0026amp; Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 100 mV peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHold-up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 ms at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mm × 90 mm × 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or panel mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (indoor use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnergy Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal capacitor for short-term voltage stability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower ON, Fault status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOvervoltage, overcurrent, short-circuit, thermal protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson ControlWave Micro series controllers and modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 V AC input\/output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 ms for transient load changes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF (Mean Time Between Failures)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 100,000 hours at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports additional modules in ControlWave Micro series for scalability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the input voltage range for the\u003cspan\u003e \u003c\/span\u003e396509-05-3\u003cspan\u003e \u003c\/span\u003emodule?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e396509-05-3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eaccepts\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100–240 V AC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einput, supporting global industrial standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What output does the\u003cspan\u003e \u003c\/span\u003e396509-05-3\u003cspan\u003e \u003c\/span\u003eprovide?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt provides a stable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 V DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoutput with a maximum current of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3 A\u003c\/strong\u003e, suitable for ControlWave Micro systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How is the\u003cspan\u003e \u003c\/span\u003e396509-05-3\u003cspan\u003e \u003c\/span\u003emounted?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIN rail\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epanel mounting\u003c\/strong\u003e, offering flexible installation options.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt operates between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0°C and 60°C\u003c\/strong\u003e, ensuring reliability in standard industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How long does shipping take?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA5:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOrders ship within\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3 days to 2 weeks\u003c\/strong\u003e, depending on quantity and logistics, using carriers like DHL.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: What if there is a quality issue?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA6:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe support\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereturns within 30 days\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor any quality problems with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e396509-05-3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in the designated slot within the Ovation I\/O chassis\u003c\/li\u003e\n\u003cli\u003eEnsure proper wiring to actuator and feedback device terminals\u003c\/li\u003e\n\u003cli\u003eVerify excitation frequency and feedback polarity before commissioning\u003c\/li\u003e\n\u003cli\u003eFollow Emerson grounding and shielding procedures\u003c\/li\u003e\n\u003cli\u003eHandle using ESD-safe practices and store in anti-static packaging\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43014852345923,"sku":"396509-05-3","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/396509-05-3EmersonPOWERSUPPLYMODULE_1.jpg?v=1772504470","url":"https:\/\/www.plcdcspro.com\/products\/396509-05-3-emerson-power-supply-module","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}