{"product_id":"1756-if16h-ab-controllogix-16-channel-hart-analog-input-module","title":"1756-IF16H | AB ControlLogix 16-Channel HART Analog Input Module","description":"\u003ch3 class=\"\"\u003eOverview\u003c\/h3\u003e\n\u003cp class=\"\"\u003e\u003cspan\u003eThe Allen-Bradley 1756-IF16H is a 16-Channel HART Analog Input Module, part of the ControlLogix platform.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 differential, current (4…20 mA, 0…20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHART Modem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated HART modem per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–20 mA, 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16…21 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage \u0026amp; Current Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e- Backplane: 5.1V DC @ 200 mA, 24V DC @ 125 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Backplane Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.02 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50V (continuous), Basic insulation type, Input Channels to Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e249 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Circuit Detection Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive full scale reading within 5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Mode Noise Rejection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e74 dB @ 50\/60 Hz (15 Hz filter), 90 dB @ 60 Hz (20 Hz filter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Noise Rejection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 90 dB @ 50\/60 Hz (15 Hz and 20 Hz filters only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetter than 0.01% of range (15 Hz and 20 Hz filters only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibrated Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetter than 0.13% of range (all filters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration Interval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 months typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOffset Drift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27 µV\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGain Drift with Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Input Scan Time (Min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11…328 ms (filter dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule HART Scan Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEstimated 1 s if all channels are HART-enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInteger mode (left justified, 2’s complement) IEEE 32-bit floating point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Conversion Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSuccessive approximation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Conversion Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-Ladder DAC, monotonicity with no missing codes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Keying\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectronic, software configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Terminal Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1756-TBCH, 1756-TBS6H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.33…2.1 mm² (22…14 AWG) solid or stranded shielded copper wire, rated at 105°C (221°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Block Torque Spec\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 N•m (4.4 lb•in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to 60 °C (32 °F to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNonoperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 °C to +85 °C (-40 °F to +185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration (Operating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 g @ 10…500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g (IEC 60068-2-27 Test Ea)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNonoperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 g (IEC 60068-2-27 Test Ea)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eCertifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ec-UL-us\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed Industrial Control Equipment, certified for US and Canada. (UL File E65584)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL Listed for Hazardous Locations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2 Group A,B,C,D (File E194810)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompliant with European EMC, Industrial Immunity, and Emissions Standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII 3 G Ex nA IIC T4 Gc (DEMKO12ATEX1219040X)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIECEx\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII 3 G Ex nA IIC T4 Gc (IECEx UL 16.0109X)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":42183956332611,"sku":"1756-IF16H","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/5810\/3107\/files\/1756-IF16H.png?v=1742987422","url":"https:\/\/www.plcdcspro.com\/products\/1756-if16h-ab-controllogix-16-channel-hart-analog-input-module","provider":"PLC DCS Pro Ltd.","version":"1.0","type":"link"}